Anaesthesi Machine MHJ-IIIB3

http://icon-icons.com/icons2/800/PNG/512/_whatsapp_icon-icons.com_65789.png  : 08111742529 - 08129123920
Dengan Yosef Setyawan

ANESTHESIA MACHINE MHJ – III B3
MHJ-IIIB1 VENTILATORNYA ADALAH SC-M3A1 (PERGERAKAN VENTILATOR MENGGUNAKAN TEKANAN
OKSIGEN) UNTUK PASIEN YANG TIDAL VOLUMENYA LEBIH DARI 170 ML, HANYA BISA MENGESET MENIT
VOLUME.
MHJ-IIIB2 & MHJ-BIIIB3 VENTILATOR ADALAH SC-M3A (PERGERAKAN VENTILATOR MENGGUNAKAN……..)
BISA DIPAKAI UNTUK DEWASA DAN ANAK, BISA MENGESET TIDAL VOLUME DENGAN PRECISI
(HXJ-2) RESPIRATOR MONITOR (BISA MEMONITOR TIDAL VOLUME, MENIT VOLUME, AIR WAY
PRESSURE, BREATHING FREQUENCY
Rp 192,916,365 Tanpa Respirator Monitor
Rp 303,376,625 Complete dengan Respirator Monitor
MHJ IIIB3 Anaesthesia Machine is a new version of MHJ IIIB series. With a state of art
technology, it has been not only a big step in the increase of reliability and safety, but also in
designation and integration of other instruments, such as anaesthesia ventilators, monitoring
units to become an anaesthesia workstation.Providing an ISO connection on the anaesthesia
circuit, it can meet the needs for semi open, semi close or closed system anaesthesia. The
machine is possible to mount two parallel vaporizers when desired for the choice of anaesthetic
drug. The machine is easy to operate.
Features :
• Adopts a two stage regulator and a high precision three gas flowmeter with ORC system,
ensures oxygen concentration not less than 25%
• Automatic N2O cut off and an unique O2 deficiency alarm device
• With Enflurane or Isoflurane vaporizer or both
• Attachable cylinder bracket
• Pneumatic driven and electric controlled anaesthesia ventilator (Optional)
• With constant volume for adults and children (With ventilator)
• Real time airway measurement
• Exhaled tidal volume and minute volume measurement (Optional)
• Stainless steel anaesthesia writing surface
Technical data :
• Gas supply : O2 : 2.7 – 5.5 MPa
N2O : 2.7 – 5.5 MPa
Air : 2.7 – 5.5 MPa
• Flow control range : O2 : 0.1 – 10 L/min
N2O : 0.1 – 10 L/min
Air : 0.1 – 10 L/min
• Oxygen deficiency alarm : as oxygen pressure is = 0.2 MPa, alarm occurs and lasts 7
seconds at least
• N2O cut off : N2O is cut off completely when O2 pressure = 0.1 MPa
• O2 flush : 50±10 L/min at O2 pressure 0.45 MPa
• Enflurane vaporizer : 0.2 – 5 Vol%, adjustable
• APL : 0.5 – 7 KPa
• SC-M3A1 anaesthesia ventilator working mode : pneumatic controlled, pneumatic driven,
time cycled, volume constant (Optional)
• Dimension : 1275 x 584 x 655 kg
• Weight : 80 kg
Standard accessories : Main unit, 1 pcs vaporizer, version IV circuit system, air supply hose,
common gas hose, patient pipeline, breathing bag, real time pressure gauge
Optional : Isoflurane vaporizer, cylinder assembly, anaesthesia ventilator, volummeter, APL
valve, O2 reducer, N2O reducer, air hose, integrated circuit, halothane vaporizer

 